<LOGO>
FM Transmitter Measurement Report
Created: 2026-03-04 06-11-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.30 MHz 5/5, 84 dBuV 00s&10s
Pilot RDS Phase Difference
6.2 kHz 4.0 kHz -89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 69 kHz 19078 10,6563
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,0 dBr 4,96 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"00s&10s " 249E 10 (Pop M) 1 0 1 1 6:10, 4.03.2026
RT
"MPB Radi "
AF EON
95.6, 96.3, 96.6, 96.9, 97.3, 97.7, 105.5 MHz F84B, 2491, 2492, 6053
FM Scope Max at: 69 kHz MIN: 9 kHz % above 76 kHz: 10,6563 Acquired: 2026/03/04 6.10.18 Total samples: 19078 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000